We are thoroughly experienced at supplying and installing many types of air conditioning system. We are equally capable of installing split system air conditioning units to serve one room, as we are installing large 2 and 3 pipe VRF / VRV air conditioning systems to commercial premises. Our works include heat load calculation, system selection and design, and we even offer free quotations.
For more information please visit our Air Conditioning information and A/C Gallery pages. We are fully experienced at supplying and installing a vast array of ventilation systems. We have carried out works ranging from basic ventilation to toilet blocks, to alterations and recommissioning of ventilation systems serving hospital operating theatres and wards.
We are able to carry out the design and supply and installation of all ventilation systems, including Heat recovery ventilation systems. Upon completion we can provide air flow rates and commissioning reports to satisfy building regulations. We also offer balancing and commissioning of existing systems.
For more information please visit our Air Conditioning information and A/C Gallery pages. We are fully experienced at supplying and installing a vast array of ventilation systems. We have carried out works ranging from basic ventilation to toilet blocks, to alterations and recommissioning of ventilation systems serving hospital operating theatres and wards.
We are able to carry out the design and supply and installation of all ventilation systems, including Heat recovery ventilation systems. Upon completion we can provide air flow rates and commissioning reports to satisfy building regulations. We also offer balancing and commissioning of existing systems.
Services
Split system air conditioning systems comprise 2 major parts, an indoor evaporator unit and an external condensing unit.
These air conditioning systems are designed to provide energy efficient comfort cooling or heating to a single space where the indoor unit is not required to condition over dispersed areas.
Twin split air conditioning systems are also available where two indoor air conditioning units can be installed to a single condensing unit.
Twin split indoor units operate in tandem with one another with a single controller to provide air conditioning heating or cooling to a single room where the space is either larger or an unusual shape.
These air conditioning systems are designed to provide energy efficient comfort cooling or heating to a single space where the indoor unit is not required to condition over dispersed areas.
Twin split air conditioning systems are also available where two indoor air conditioning units can be installed to a single condensing unit.
Twin split indoor units operate in tandem with one another with a single controller to provide air conditioning heating or cooling to a single room where the space is either larger or an unusual shape.
We are able to design, supply and install kitchen extract and fresh air ventilation systems for commercial kitchens.
It is a requirement under BESA DW172 that kitchen extract ventilation systems are properly designed to provide adequate extraction, and where required fresh make up air.
Extract canopies should be installed at a specific height.
They should be installed with sufficient overhang over the cooking appliances.
This ensures capture of the cooking fumes and grease laden air.
When gas cooking appliances are used it is essential that mechanical fresh air make up is provided as a percentage of the extracted air.
It is a requirement under BESA DW172 that kitchen extract ventilation systems are properly designed to provide adequate extraction, and where required fresh make up air.
Extract canopies should be installed at a specific height.
They should be installed with sufficient overhang over the cooking appliances.
This ensures capture of the cooking fumes and grease laden air.
When gas cooking appliances are used it is essential that mechanical fresh air make up is provided as a percentage of the extracted air.
Air source heat pumps (air to water heat pumps) are a highly energy efficient means of heating water.
These systems use latent heat in the ambient air to generate heat energy that is transferred by heat exchangers to provide space heating and hot water heating.
Air source heat pumps are capable of operating as standalone systems capable of satisfying all hot water demands.
Air source heat pumps typically operate at around 55-60degC as low temperature hot water systems.
Although many air source heat pumps can be configured into cascade arrangements, and/or to interlink with solar panels and gas boilers.
These systems use latent heat in the ambient air to generate heat energy that is transferred by heat exchangers to provide space heating and hot water heating.
Air source heat pumps are capable of operating as standalone systems capable of satisfying all hot water demands.
Air source heat pumps typically operate at around 55-60degC as low temperature hot water systems.
Although many air source heat pumps can be configured into cascade arrangements, and/or to interlink with solar panels and gas boilers.
We carried out the supply and installation of a large 112kW 3 Pipe Heat Recovery VRF / VRV Air Conditioning system to serve the upper floor offices.
The building comprises a significant proportion of glazing around the perimeter of the building that contributes to excessive heat gains.
The windows face all directions and so the effect of overheating moves from one side of the building to the other during the course of the day.
The installation of a 3 pipe VRF/ VRV heat recovery air conditioning system allows not only provide heating and cooling to all rooms simultaneously, but also allows diversity across the system.
The building comprises a significant proportion of glazing around the perimeter of the building that contributes to excessive heat gains.
The windows face all directions and so the effect of overheating moves from one side of the building to the other during the course of the day.
The installation of a 3 pipe VRF/ VRV heat recovery air conditioning system allows not only provide heating and cooling to all rooms simultaneously, but also allows diversity across the system.
Reviews
Be the first to review Thoroughvent.
Write a Review